47
The content of each 500 IU vial of Berinert
®
therapy is
shown in Table 14.
The Mix2Vial
™*
, needleless transfer system, is available
for the reconstitution and subsequent removal of
Berinert
®
solution (Figure 24). It offers the following ad-
vantages:
•
Simplifies product preparation for quick and easy
reconstitution
•
Eliminates risk of needlestick injury, with correct use
•
Integrates a filter (15 µm), helping to ensure small
particle sizes in solution
•
Works with all syringes, including those with a
Luer-Lok
™
connection.
Dosage
* Mix2Vial™ is supplied in most countries.
Figure 24 – Mix2Vial
™
Transfer System* Simplifies the
Administration Process of Berinert
®
and Eliminates
t Risk of Needlestick Injury During Recons itution
Water
Blue side of the adapter
Integrated filter
Concentrate adapter
Concentrate