CSL Behring Monograph Berinert - page 70

69
5. With one hand grasp the product-side
of the Mix2Vial set and with the other
hand grasp the solvent-side and unscrew
the set carefully into two pieces. Discard
the solvent vial with the blue Mix2Vial
adapter attached.
6. Gently swirl the product vial with the
transparent adapter attached until the
substance is fully dissolved. Do not shake.
7. Draw air into an empty, sterile syringe.
While the product vial is upright, connect
the syringe to the Mix2Vial’s Luer Lock
fitting. Inject air into the product vial. Use
the syringe provided with the product.
Withdrawal and application
8. While keeping the syringe plunger
pressed, invert the system upside down
and draw the solution into the syringe by
pulling the plunger back slowly.
9. Now that the solution has been
transferred into the syringe, firmly hold
on to the barrel of the syringe (keeping
the syringe plunger facing down) and
disconnect the transparent Mix2Vial
adapter from the syringe.
7. MARKETING AUTHORISATION HOLDER
CSL Behring GmbH
Emil-von-Behring-Strasse 76
35041 Marburg
Germany
8. MARKETING AUTHORISATION NUMBER
- country specific -
9. DATE OF FIRST AUTHORISATION/
RENEWAL OF THE AUTHORISATION
- country specific -
10. DATE OF REVISION OF THE TEXT
September 2013
Product Information
1...,60,61,62,63,64,65,66,67,68,69 71,72,73,74,75,76,77,78
Powered by FlippingBook